EIG Biomedical Tampa, FL

Platform

A polymer is a schedule you can hold in your hand.

Bioresorbable polyesters degrade by hydrolysis at rates set by their chemistry. Choose the polymer, the copolymer ratio, the molecular weight and the geometry, and you have chosen how long the implant stays strong, how fast it gives up its payload, and when it is gone. Every EIG program is the same engineering problem solved with different settings.

How a Guard™ product behaves in situ

Four stages, in order.

Stage 01

Place

Deployed during the index procedure — into a resection cavity, along a mucosa, or across a defect. No separate intervention and no change to the operation already planned.

Stage 02

Protect

The construct does mechanical work: managing dead space, maintaining a cavity for imaging, lining tissue against luminal contents, or covering an exposed surface.

Stage 03

Release

Payload leaves the matrix by diffusion first and polymer erosion after, producing weeks of sustained local concentration with minimal systemic exposure.

Stage 04

Resorb

Ester bonds hydrolyse to metabolites the body already clears. Nothing remains to retrieve or explant.

Materials

The polymer sets the clock.

We build from medical-grade bioresorbable polyesters with decades of clinical history as sutures, screws and scaffolds. Selection is driven by the window each indication demands.

Indicative behaviour of the polymer families used across the portfolio
PolymerStrength retentionFull resorptionWhy we reach for it
PLGADays → months≈ 1–6 monthsThe most tunable option and the workhorse for elution. Copolymer ratio and molecular weight move degradation across a wide range.
PDO≈ 4–6 weeks≈ 6 monthsFlexible and tough, with a strength curve that holds through an early dwell window. Long clinical history as monofilament suture.
PLA / PLLAMonths≈ 12–24 monthsUsed as a modifier to fine-tune degradation rate and adjust mechanical behaviour rather than as a standalone body.
PCLMonths≈ 2–3 yearsSlow, ductile and low-melting. In a blend it supplies elastic recovery and compressibility, and moderates burst release.

Figures above are published ranges for these polymer families, not EIG specifications. Each program commits to its own composition and geometry, established by bench and animal testing and disclosed under agreement.

Payload

Dose the tissue, not the patient.

A resection bed is a compartment. Releasing an agent into that compartment from a matrix sitting inside it produces local concentrations systemic dosing cannot reach, at systemic exposures systemic dosing cannot avoid.

We work with agents that are already approved and characterised. That is a deliberate choice: it removes novel-molecule risk from the program and puts the innovation where it belongs — in the delivery.

Release is shaped, not accepted. Payload loading, layer thickness, matrix porosity and surface area are all design inputs, and together they determine the size of the initial release and the length of the plateau that follows. Payload selection is program-specific and is not disclosed publicly.

Regulatory posture

Device-led, and argued that way from the start.

A drug-eluting bioresorbable implant is a combination product under 21 CFR Part 3. Which FDA centre leads review shapes the evidence package, the timeline and the cost of everything downstream — so we engage the Office of Combination Products early and in writing rather than discovering the question late.

EIG's position across the portfolio is that the therapeutic effect originates with the device. The construct determines where the payload goes, how long it stays and what mechanical work happens meanwhile. On that reading the most significant safety and effectiveness questions — degradation kinetics, retention, biocompatibility, mechanical integrity, manufacturing — are device questions, and CDRH is the appropriate lead centre with CDER consulting on the drug constituent.

Center assignment is determined by FDA, not by the sponsor. The positions described here are EIG's proposed analyses under 21 CFR 3.2(m) and 3.4(b) and are not FDA determinations.

Development path

The same five steps for every program.

Programs enter at different points depending on maturity, but the sequence does not change. Each step is designed against what the next submission will require.

Step 01

Formulate

Polymer selection and payload loading committed to a single specification; release measured in vitro across the target window.

Step 02

Characterise

Mechanical handling, degradation kinetics, sterilisation compatibility and stability, run to written protocol with independent test houses.

Step 03

Qualify

GLP biocompatibility to the ISO 10993 series, plus disease-relevant animal models measuring local and systemic exposure and tissue response.

Step 04

First in human

Feasibility study under IDE: safety, wound healing, device handling and placement, local pharmacokinetics and early biological signal.

Step 05

Pivotal

Randomised trial of standard of care with and without the device, powered on a local-control endpoint, supporting a De Novo submission.

Intellectual property

Issued and building.

The platform is covered by an issued U.S. patent granted in November 2025, with further applications pending across platform chemistry, device geometry and indication-specific configurations.

Development follows FDA design-control expectations, with biocompatibility testing planned to the ISO 10993 series, terminal sterilisation validated to ISO 11135, and preclinical work run through established contract research organisations.

Want the technical detail behind any of this?

Formulations, release data and program specifics are shared with qualified parties under confidentiality.